SOLAS III/20.8.1
The regulation requires every inflatable lifejacket to undergo servicing:
At intervals not exceeding 12 months.
At an approved servicing station.
By properly trained personnel using suitable facilities.
With an exceptional extension up to 17 months, only when authorized by the flag Administration.

 

Period Inherently buoyant Inflatable
Weekly No specific individual weekly inspection mandated by SOLAS III/20.6 Same
Monthly Onboard inspection Onboard inspection
12 months No universal annual servicing requirement under SOLAS III/20.8 Mandatory servicing at approved station
17 months Not applicable Maximum exceptional extension with flag Administration approval
5 years No universal periodic servicing requirement No separate universal 5-year test prescribed by SOLAS III/20.8