MSC/Circ.1047 covers the monthly crew inspection. MSC/Circ.1114 covers the periodic air leak test. Both are IMO guidelines for immersion suits and anti-exposure suits under SOLAS Chapter III. classnk.com

IMO circular MSC/Circ.1047 Monthly, by the ship’s crew under SOLAS III/20.7 Check the storage bag, donning instructions, suit type and size, fabric condition, zipper operation, reflective tape, and light and whistle where fitted. If the suit has an inflatable head support or buoyancy ring, leak-test it at least quarterly. This quarterly check excludes integral inflatable lifejackets.

MSC/Circ.1114 Every 3 years at most, with more frequent testing for suits over 10 years old, according to flag instructions Air-test each suit at 0.7–1.4 kPa (7–14 mbar) and apply soapy solution to seams and closures. Growing bubbles indicate a leak. This can reveal deterioration that a visual inspection misses.

For onboard service: MSC/Circ.1114 allows the air test onboard when suitable equipment is available and recommends a suitable shore facility. Before quoting, check the vessel’s flag instructions for the interval on suits over 10 years old and who may carry out the onboard test.