+34 661 707 124
Torres de Hercules, Crtra Termica, 11379, Los Barrios, Cadiz, Spain

Oil Content Meter 15ppm Alarm

15PPM ALARM, OILY WATER SEPARATOR AND OIL CONTENT METER SERVICE POINT GIBRALTAR

CELL REPLACING AND RETROFITTING BY BRAND NEW BILGE ALARM FOR:

GEORIM: GBA150
FELLOW KOGYO: FOCAS 1500, FOCAS 1800
BRANNSTROM: Bilgmon 488
RIVERTRACE ENGINEERING: Smart Bilge
JOWA: SeAguArd
MARSEN: BOA-2000

In compliance with the IMO, SOLAS and RESOLUTION MEPC.107(49) Adopted on 18 July 2003 REVISED GUIDELINES AND SPECIFICATIONS FOR POLLUTION PREVENTION EQUIPMENT FOR MACHINERY SPACE BILGES OF SHIPS

4.2.11 The accuracy of the 15 ppm Bilge Alarms should be checked at IOPP Certificate renewal surveys according to the manufacturers instructions. Alternatively the unit may be replaced by a calibrated 15 ppm Bilge Alarm. The calibration certificate for the 15 ppm Bilge Alarm, certifying date of last calibration check, should be retained onboard for inspection purposes. The accuracy checks can only be done by the manufacturer or persons authorized by the manufacturer.

4.2.9 In the event the 15 ppm Bilge Alarm is replaced, means should be provided to ensure the data recorded remains available on board for 18 months.

PETRIK NAVAL MEETS THE REQUIREMENTS OF THE

Annex I of MARPOL 73/78
Regulation 14.7
Regulation 14 Oil filtering equipment

Interpretation
For application of resolution MEPC.107(49), the phrase “The accuracy of the 15 ppm Bilge Alarms should be checked at IOPP Certificate renewal surveys according to the manufacturer’s instructions” in 4.2.11 shall be interpreted as follows considering resolution A.1104(29):

a) The validity of calibration certificate should be checked at IOPP annual/intermediate/renewal surveys.

b) The accuracy of 15 ppm bilge alarms is to be checked by calibration and testing of the equipment conducted by a manufacturer or persons authorized by the manufacturer and should be done at intervals not exceeding five years or within the term specified in the manufacturer’s instructions, whichever is shorter.

ACCURACY CHECK FOR :

BRANNSTROM: Bilgmon 488
RIVERTRACE ENGINEERING: Smart Bilge

IOPP turn key solution for oily water separator
Petrik Naval offers to their customers a complete renewal of the oily water separator measuring cell with universal one on a very reasonable price.

BRANDS: Brannstrom Bilgmon, Xiaman Xingsha Instruments, Georim Engineering GBA150, Fellow Kogyo, Jowa, Wartsila, SKF, Alfa Laval, RWO Marine Water Technology, Victor Marine, Recovered Earth Technologies, DongHwa Entec, Petroind, China Deyuan Marine, Ocean Clean GmbH, Kohn Industry, Falck Formco, Marlins, Veolia

PARTNERS: Brannstrom Bilgmon, Rivertrace Engineering and Rongded Shanghai

SERVICE PORTS: Gibraltar, Algeciras, Huelva, Malaga, Santander, Cadiz, Castellon, Valencia, Cartagena, Barcelona, Taragona, La Coruña, Bilbao, Malaga, Rotterdam, Antwerp, Sines, Setubal